LEYUN · SITE SPEC & COMPONENT LIBRARY独立站技术规范手册

Tolerance Table Template and Dimension Marking Rules

Section:DATA TABLE SPEC · Reviewed:2026-11-20 · Template asset

Key takeawayThis section defines the structure template, field dictionary, integration points and compliance boundaries for 「Tolerance Table Template and Dimension Marking Rules」 in DATA TABLE SPEC. Templates are for reference only; verify local regulations and platform rules before launch.

Industries and use cases

  • Machined products where buyers always ask about tolerances
  • Categories where a mismatch between drawing and part leads directly to a dispute
  • Sites that must distinguish standard tolerances from optional precision
  • Buying processes that compare quotations by tolerance class
Template / code snippethtml
<table class="tol-table">
  <caption>${modelCode} 关键尺寸公差(默认)</caption>
  <thead>
    <tr>
      <th scope="col">尺寸项</th>
      <th scope="col">标称值</th>
      <th scope="col">默认公差</th>
      <th scope="col">可选精度</th>
      <th scope="col">检测方式</th>
    </tr>
  </thead>
  <tbody>
    <tr>
      <th scope="row">工作行程</th>
      <td>300 mm</td>
      <td>±0.10 mm</td>
      <td>±0.05 mm</td>
      <td>高度尺</td>
    </tr>
    <tr>
      <th scope="row">工作台平面度</th>
      <td>—</td>
      <td>0.05 mm</td>
      <td>0.03 mm</td>
      <td>平尺 + 塞尺</td>
    </tr>
    <tr>
      <th scope="row">主轴与工作台垂直度</th>
      <td>—</td>
      <td>0.08 mm</td>
      <td>按图纸</td>
      <td>百分表</td>
    </tr>
  </tbody>
</table>

<p class="tol-note">
  未列出的尺寸按图纸标注执行;
  未特别注明的公差按 ${defaultStandard} 执行。
  可选精度项的加价与交期在下单前确认。
</p>
Fields and parameters
Field / parameterTypeDescription and values
Dimension itemTextNamed the same way as on the drawing
Nominal valueNumber + unitNominal value for critical dimensions
Default toleranceNumber ± unitTolerance in the standard configuration
Optional precisionTextHigher precision that can be achieved
Inspection methodTextInstrument or method, for acceptance
General tolerance noteParagraphDefault standard for dimensions not listed

SEO and structured-data notes

SEO and structured-data checkpoints
Tolerances need a sign"0.1 mm" and "±0.1 mm" are two different things in engineering
State the inspection methodDifferences between instruments are a common source of acceptance disputes
Declare the general toleranceWithout a rule for unlisted dimensions, acceptance turns into an argument over whose standard applies
Note the surcharge and lead time for optional precisionOtherwise buyers assume higher precision is included at no cost
Keep the table and the drawing consistentWhere they conflict, which document prevails must be agreed in advance
Prioritise critical dimensionsList only the items that affect assembly and performance; a full dimension list buries the point

Compliance risk notes

  • Tolerance figures must not be overstated
  • Claims of "zero error" or "absolute precision" must not be made
  • Optional precision must be genuinely achievable
  • Where the page conflicts with the drawing, the governing document must be stated
  • Tolerances for safety-related fits must not be relaxed

Do not reuse this template verbatim in regulated contexts; verify local regulations and platform rules before going live.

Modification example

<!-- Modification example: add the general tolerance rule and the inspection method -->
<!-- Original -->
<tr><th scope="row">Working stroke</th><td>300</td><td>±0.1</td></tr>

<!-- Modified -->
<tr>
  <th scope="row">Working stroke</th>
  <td>300 mm</td>
  <td>±0.10 mm</td>
  <td>±0.05 mm (surcharge, lead time to be confirmed)</td>
  <td>Height gauge, room temperature 20 ± 2 °C</td>
</tr>

<p class="tol-note">
  This table lists the default tolerances of critical dimensions.
  Dimensions not listed follow the markings on the customer drawing;
  where the drawing carries no marking, ${defaultStandard} applies.
  Optional precision requires price and lead time to be confirmed before ordering.
</p>

<!-- Three key reinforcements:
     1. the unit mm is written into the nominal value
     2. optional precision is marked "surcharge to be confirmed", so it is not read as free
     3. the general tolerance rule plus the order of precedence when documents conflict —
        this paragraph prevents most acceptance disputes -->

FAQ

How many items should a tolerance table list?
Five to twelve critical dimensions. Listing every dimension leaves the reader without a focus and removes any guidance value.
Which standard should the general tolerance use?
Choose one per your drawing conventions and state the standard number. The essential sentence is "where not marked, this applies"; it is dispute prevention in itself.
Should the tolerance table be merged into the specification table?
Keep them as separate tables or separate blocks. The specification table answers "what it is", the tolerance table answers "to what accuracy".
Should the surcharge for optional precision be stated?
Yes. Buyers assume higher precision is part of the default configuration, and silence creates disagreement at the quotation stage.
Version notes2026-11-20: first release, compiled from official Google documentation and public technical sources; updated as engine rules change. Engine behaviour details follow the latest official Google documentation.

Note: this page is a summary of publicly documented search-engine rules and is for self-check reference only. Engine behaviour is subject to the latest official Google documentation; verify against your own Search Console data.